The Growatt MID 40KTL3-X inverter is a cutting-edge device designed for solar power systems, renowned for its high efficiency and reliability.
The Growatt MID TL3-X inverter is a reliable and efficient solution for converting DC power from solar panels into usable AC power for residential and commercial applications. It offers a user-friendly design with easy installation and operation.
–One of its standout features is its large capacity, with a rated output power of 40 kilowatts, making it suitable for medium to large-scale solar installations. This makes it an ideal choice for commercial and industrial applications where substantial power generation is required.
–The inverter is equipped with advanced MPPT (Maximum Power Point Tracking) technology, optimizing the power output from the solar array by continuously tracking and adjusting to the maximum power point. This ensures maximum energy harvest even in varying weather conditions or shading.
–Additionally, the MID 40KTL3-X boasts a rugged and durable design, suitable for outdoor installations. Its IP65-rated enclosure provides protection against dust and water ingress, ensuring long-term performance and reliability in harsh environmental conditions.
The following are some descriptions of Growatt MID-X series inverter 30kw-40kw, if you need the full datasheet, please contact our sales team.
|
MID 30KTL3-X
|
MID 33KTL3-X
|
MID 36KTL3-X
|
MID 40KTL3-X
|
Input data (DC)
|
||||
Max. recommended PV power (for module STC)
|
45000W
|
49500W
|
54000W
|
60000W
|
Max. DC voltage
|
1100V
|
|||
Start Voltage
|
250V
|
|||
Nominal voltage
|
600V
|
|||
MPPT voltage range
|
200V-1000V
|
|||
No. of MPP trackers
|
3/3/4/4
|
|||
No. of PV strings per MPP tracker
|
2
|
2
|
2
|
2
|
Max. input current per MPPT tracker
|
26A | 26A | 26A | 26A |
Max. short circuit current per MPPT
|
32A
|
32A
|
32A
|
32A
|
Output data (AC)
|
||||
Rated AC output power
|
30000W
|
33000W
|
36000W
|
40000W
|
Max. AC apparent power
|
33300VA
|
36600VA
|
39600VA
|
44000VA
|
Nominal AC voltage(range*)
|
220V/380V, 230V/400V (340-440V)
|
|||
AC grid frequency;(range*)
|
50/60 Hz (45-55Hz/55-65 Hz)
|
|||
Max. output current
|
50.5A
|
55.5A
|
60A
|
66.6A
|
Adjustable power factor
|
0.8leading…0.8lagging
|
|||
THDi
|
<3%
|
|||
AC grid connection type
|
3W+N+PE
|
|||
General data
|
||||
Dimensions (W / H / D)
|
|
580/435/230mm
|
||
Weight
|
29.5kg
|
29.5kg
|
30.5kg
|
30.5kg
|
Operating temperature range
|
-25 °C … +60 °C
|
|||
Self-Consumption (night)
|
<1W
|
|||
Topology
|
Transformerless
|
|||
Cooling
|
Natural convection
|
|||
Protection degree
|
IP66
|
|||
CE, VDE0126, Greece, EN50549, C10/C11, UTE C 15-712, IEC62116, IEC61727, IEC 60068, IEC 61683, CEI0-21, N4105, TOR Erzeuger
G98/G99, G100, AS4777, UNE217001, UNE206007, PO12.2 |
In the following table you will find the accessories and parts inside the package of the inverter
Object
|
Description
|
Quantity
|
Object
|
Description
|
Quantity
|
A
|
Inverter
|
1
|
I
|
PV terminal shell
|
6 /6
|
B
|
Wall mount
|
1
|
J
|
PV terminal core
|
6 /6
|
C
|
Quick Guide
|
1
|
K
|
Security screw
|
1
|
D
|
AC waterproof cover(just for Vietnam models)
|
1
|
L
|
COM port removal tool
|
1
|
E
|
Datalogger
|
1
|
M
|
PV terminal removal tool
|
1 |
F
|
COM port signal connector
|
1
|
N
|
14-6 0 terminal
|
6
|
G
|
Expansion screw
|
4
|
O | Fixed AC side water proof cover M4*10 screw | 4 |
H
|
Plastic expansion tube
|
4
|